TitleProduct

HVAC System 5 Ton Cooling and Heating Rooftop Package Unit

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shanghai

  • Validity to:

    Long-term effective

  • Last update:

    2017-07-11 05:19

  • Browse the number:

    138

Send an inquiries

Company Profile

Shanghai Shenglin M&E Technology Co., Ltd.

By certification [File Integrity]

Contact:Ms. Bella(Mr.)  

Email:

Telephone:

Phone:

Area:Shanghai

Address:Shanghai

Website: http://cnshenglintec.cnzhenghang.com/

Product Details


Rooftop air conditioner

Features
Description:
1. Air cooled rooftop air conditioner.
2. Cooling capacity: 8kw to 90kw, a variety of choices.
3. High external pressure.
4. Applicable to residential and commercial buildings, hotels, and scientific research units, factories and enterprises and so on.

Feature:
1. Evaporator: Type Inner grooved copper tube and aluminum fin
2. Fin Type 5* :Slotted fin hydrophilic aluminum fin
3. Condenser: Type Inner grooved copper tube and aluminum fin
4. Fin Type 5* :Rippled hydrophilic aluminum fin
5. Condenser Fan Type: Low noise axial type


Technical Data
GT-WKR Series-Roof Top AH Specifiaction 1
Model GT-WKR- 10 15 18 20 25 30 35
Specification Cooling capacity 1* kW 10.5 15.0 18.5 21.0 26.3 29.8 35.0
Heating capacity 2* kW 11.5 15.9 19.5 22.1 27.6 32.6 37.1
Supply air 3* m3/h 1800 2400 2900 3500 4500 5000 5800
Static pressure 3* Pa 100 150 150 180 200 250 250
Noise 4* dB(A) 60 60 62 62 65 65 68
Power 3N-380V-60Hz
Total capacity 3.9 5.74 7.0 8.27 9.96 11.0 14.15
Color White
ooling system Compressor Type Efficient scroll closed 
Quantity 1 1 1 1 1 1 2
Supply air fan Type Low noise centrifugal type
Capacity kW 0.37 0.55 0.75 0.75 1.1 1.5 2.2
Evaporator Type Inner grooved copper tube and aluminum fin
Fin type 5* Slotted fin hydrophilic aluminum fin
Condenser Type Inner grooved copper tube and aluminum fin
Fin type 5* Rippled hydrophilic aluminum fin
Condenser fan Type Low noise axial type
Quantity 1 1 1 1 1 1 2
Refrigerant Refrigerant R22/R407C
Refrigerant control External balance type thermal expansion valve
Air filter Initially effect plate filter
Dimensions L mm 1400 1400 1600 1600 1850 1850 2200
W mm 1050 1050 1200 1200 1400 1400 1800
H mm 1050 1050 1050 1050 1200 1200 1520
Weight kg 200 230 260 300 550 600 850
  1. Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
  2. Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6ºC;
  3. The air volume and static pressure`s specification in the table is standard, and can be designable.
  4.  Noise data is measured in the front of the units when cooling under the standard air volume.
  5.  Fin type and material can be designable. 
GT-WKR Series-Roof Top AH Specifiaction 1
Model GT-WKR- 40 50 60 70 90 110 120
Specification Cooling capacity 1* kW 42.0 52.8 61.2 70.2 87.5 105.1 122.5
Heating capacity 2* kW 44.1 55.4 62.5 73.8 92.8 112.0 130.0
Supply air 3* m3/h 7000 8600 10000 12000 14500 17000 20000
Static pressure 3* Pa 300 300 300 350 350 400 400
Noise 4* dB(A) 68 69 69 70 71 72 72
Power 3N-380V-60Hz
Total capacity 17.24 20.72 23.0 29.76 39.1 44.66 51.58
Color White
ooling system Compressor Type Efficient scroll closed
Quantity 2 2 2 2 2 4 4
Supply air fan Type Low noise centrifugal type
Capacity kW 2.2 3 4 4 5.5 7.5 7.5
Evaporator Type Inner grooved copper tube and aluminum fin
Fin type 5* Slotted fin hydrophilic aluminum fin
Condenser Type Inner grooved copper tube and aluminum fin
Fin type 5* Rippled hydrophilic aluminum fin
Condenser fan Type Low noise axial type
Quantity 2 2 2 4 4 4 4
Refrigerant Refrigerant R22/R407C
Refrigerant control External balance type thermal expansion valve
Air filter Initially effect plate filter
Dimensions L mm 2200 2600 2600 3200 3200 6000 6000
W mm 1800 2200 2200 2200 2200 2300 2300
H mm 1520 1700 1700 1900 1900 2300 2300
Weight kg 850 1100 1250 1400 1650 1850 2200

Note:
1. Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
2. Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6ºC;
3. The air volume and static pressure`s specification in the table is standard, and can be designable.
4. Noise data is measured in the front of the units when cooling under the standard air volume.
5. Fin type and material can be designable. 






Name: Alina
Tel: 0086 021 35324169-207
Mob: 0086 18321717548